Accurate measurement of tandem and triple types of photovoltaic modules. |
| » |
Pulsed light is used, ensuring stable measurement. |
| » |
Measurement of slow responding photovoltaic modules is also possible. |
| » |
No need to reverse modules, facilitating in-line operation. |
| » |
Our unique IPS technology enables high-speed measurement with a measuring time of 7 seconds and a cycle time of 27 seconds per module. |
| » |
Our unique irradiance adjustment method maintains irradiance non-uniformity within ± 4%. |
| |
|
| |
Specifications :
|
| Model |
PVS 1114iD |
| Effective irradiation area |
1100 mm × 1400 mm |
| Light source |
Xenon and halogen lamps |
| Spectrum |
Within ±25% spectral match for the reference solar radiation of AM1.5 specified under JIS C 8911 for wavelength bands of 350 to 500, 500 to 600, 600 to 700, 700 to 800, 800 to 900 and 900 to 1100 nm. |
| Measured luminance |
1000W/m 2 |
| Non-uniformity in irradiance |
Within 4% |
| Temporal instability of irradiance |
Within ±0.2% (*) JIS C 8192 temporal instability of irradiance: Grade A |
| Re-measurement accuracy |
Pmax: Within ±0.5% |
| Power supply |
3-phase, AC 200 to 220 V, 50/60 Hz, 180 A |
| Dimensions (L×W×H) |
4.90 m × 4.10 m × 2.05 m |
|
| |
| |
| |
|
| |
|
| » |
Module guide (Manual / automatic transfer) |
| » |
Measurement probe arm |
| » |
Hi-pot test function |
| |
|